AHAM HRF 1 2008 PDF

AHAM HRF 1 2008 PDF

Energy and Internal Volume of Refrigerating Appliances AHAM HRF pi AHAM HRF PREFACE The Association of Home. BY ORDER OF THE EXECUTIVE DIRECTOROffice of the Federal RegisterWashington, Authority of the Code of Federal Regulations. Energy and Internal Volume of Refrigerating Appliances – AHAM HRF This standard establishes a uniform, repeatable procedure and standard methods.

Author: Mezizahn Mazut
Country: Canada
Language: English (Spanish)
Genre: Automotive
Published (Last): 7 July 2018
Pages: 390
PDF File Size: 10.91 Mb
ePub File Size: 15.73 Mb
ISBN: 121-7-57943-722-9
Downloads: 87731
Price: Free* [*Free Regsitration Required]
Uploader: Fauzahn

Please first verify your email before subscribing to alerts.

Turning off the ice maker for the purposes of the energy test shall only stop the further harvesting of ice. Already Subscribed to this document.

AHAM HRF-1: Household Refrigerators, Combination Refrigerator-Freezers, and Household Freezers

The average per-cycle energy consumption for a cycle type Section 3. The defrost heater shall not either function or turn off differently during the energy test than it would when in typical room conditions.

Record temperature measurements at the locations prescribed in Figures and For long-time automatic defrost models, compartment temperatures shall be those measured in the first part of the test period specified in Section 5. The items below shall be considered as being in place and their volumes deducted: Record the locations selected. For wine chillers, basic refrigerators and refrigerator-freezers, if the interior arrangements of the cabinet do not conform to those shown in Figure and Figuremeasurements shall be taken at selected locations chosen to represent approximately the entire refrigerated compartment Each compartment shall have the number of thermocouples specified in Figure and Figure The recorded temperature shall be the average temperature at that point during a cycle Section 3.

  HYDROTHERM 46M PDF

Containers and covers, and food shelves are not to be removed. If the model has the quick freeze option, it shall be used to bypass the temperature control. If the interior arrangements of the cabinet do not conform with those shown in Figuremeasurements shall be taken at selected locations chosen to approximately represent the entire freezer compartment Section 3. If the interior arrangements of the cabinet do not conform with those shown in Figuremeasurements shall be taken at selected locations chosen to approximately represent the entire fresh food compartment Section 3.

Unless otherwise specified, cabinet doors shall be kept closed during all tests. Electric heaters that would normally operate at typical room conditions with door openings shall also operate during the energy test.

AHAM HRF new_百度文库

The standard methods and the recommended levels of performance, where they appear, are intended to provide a means by which different brands and models of refrigerators, wine chillers and freezers can be compared and evaluated. For refrigerators and refrigerator-freezers: This standard is not included in any packages.

A compartment provided for the storage of butter, margarine, cheese and similar products. They shall relate to actual use conditions and be technically and scientifically sound.

Subscription pricing is determined by: One which is less than either the width or the depth, or both, of the full shelf. An external drawer that is designed to pull 20008 tip out.

Ahma recorded temperature of the freezer compartment shall be the average of the temperatures recorded at the locations shown in Figure All standards must be updated or reconfirmed at least every five years.

The “run-in” may be made at any convenient room temperature. Add to Alert PDF. NOTE In order to keep packages from shifting and destroying the air gap, a wire grid with small, non-thermally conductive spacers for contact with freezer liner may be used. For types 5 and 6; ayam height dimension shall be measured from the bottom of the liner or from the top of a trivet, if furnished. Unless the area is obstructed by shields or baffles, the gradient shall be maintained from 2 inches 5.

  EEN DIGITAAL MARKETINGPLAN IN 100 DAGEN PDF

Item Detail – AHAM HRF (Energy & Volume Refrigerating Appliances)

The volume of the evaporator space see Section 4. The standard methods are not intended to inhibit improvement and innovation in product testing, design or performance. Ayam types 1, 2, 3 and 4; the height dimension shall be measured from the bottom of the liner or from the top of a trivet, if furnished to a plane defining the gasket sealing surface. Please first log in with a verified email before subscribing to alerts. The recorded temperature of the wine storage compartment shall be the average of the temperatures recorded at the three locations shown in Figure Otherwise, it shall be run only in the highest energy use position ahqm each temperature control setting.

The recorded temperature of the fresh food compartment shall be the average of the temperatures recorded at the three locations shown in Figure One that can have its vertical position changed without the use of tools.